Dilatometers


Dilatometers are used to measure the dimensional change of a material (ceramics, glasses, metals, composites, carbon/graphite, minerals, polymers, and others) as a function of temperature.

A standard dilatometer test determines both reversible and irreversible changes in length (expansion and shrinkage) during heating and cooling, and pinpoints where reactions occur that cause expansion or contraction.

An Orton dilatometer can be used to determine Coefficient of Thermal Expansion (CTE), softening point, glass transition temperature, curie point, crystalline transformation, phase transition, shrinkage, warping, bloating, sintering rate, isothermal creep, and stress relaxation. With a dilatometer, test samples are quickly and easily measured for determining firing ranges and firing schedules, measuring thermal expansion ranges for glaze fits, and measuring thermal expansion ranges for R&D, QC or product certification.

Horizontal Orton Dilatometers (ASTM-E228)

The main advantage of the horizontal system is the uniform temperature zone for the sample. Most tests are performed with a horizontal unit.
The sample is positioned between the end of the sample holder and the probe rod. After positioning the sample in the sample holder, the furnace is moved horizontally to cover the sample and sample holder.
The probe rod extends from the end of the sample, through the sample holder tube, and connects to the displacement sensor assembly outside the furnace. The probe rod is under load outside the furnace to keep it in constant contact with the sample, even when shrinking.

Dilatometers for Plastics (ASTM-D696)


Determine thermal expansion coefficient between -30C to +30C with Fused Silica sample holder system.
Dial gage systems with temperature controlled sample bath.

The sample specimen is placed inside a silica tube holder, A probe rod extends from the end of the sample, within the sample holder tube and contacts the dial gage. The sampleholder is placed into a temperature controlled bath for expansion measurements from -30C to +30C.

NOTE: These dilatometers for plastics are special order and require extra delivery time.

Dual Position Horizontal Dilatometers

Dual sample dilatometers allow 2 samples to be tested at one time, Dual systems can be configured for 2 test specimens for increased throughput or 1 test specimen and a 1 reference sample for differential analysis.

The samples are positioned between the end of the sample holder and the probe rods. After positioning the sample in the sample holder, the furnace is moved horizontally to cover the samples and sample holder.
Probe rods extends from the ends of the samples, through the sample holder tube, and connects to displacement sensors outside the furnace. The probe rods are under load outside the furnace to keep it in constant contact with the samples, even when shrinking.

NOTE: Dual systems are special order and require extra delivery time.

Computer Analysis
Every Orton dilatometer is supplied with the application software to be installed on the enduser's PC in order to acquire, save and analyze the data generated. The Orton Dilatometer Software is written for Windows based personal computers. For Standard Horizontal dilatometers,the software allows the test to be remotely programmed and started.  It can be used to monitor the test in real time, or can be used to examine the data after the test cycle. The software imports the data through the USB interface and stores it on the hard drive for post-testing analysis.


Model 1410 B





General

Orton Dilatometer 1410B is a basic horizontal, digital dilatometer that measures the expansion or contraction of a single test specimen from room temperature to 1000C with on-board, stand-alone, programmable process controller and measuring head assembly equipped with LVDT sensor.

Operated according to ASTM E-228, ASTM C-372, or ISO 7991


Includes

  • Bench top instrument console
  • 1000C horizontal tube furnace
  • programmable process controller
  • LVDT measuring head
  • Fused quartz sample holder and probe rod
  • type "N" thermocouple,
  • 1 (25.4mm) or 2" (50.8mm) calibration sample
  • computer software
  • Accessories and instruction manual. (Computer not included.)
Specification :

Model  :  DIL 1410 B
Warranty  :  12 Months
Temperature Range  :  RT to 1,000C
Furnace  :  Tube style, 8 inch heated zone
Thermocouple  :  Type "N" 2 wire
Sample Holder and Probe Rod  :  Fused Quartz
Sample Size (max) :  50 mm long x 20 mm round or square
LVDT Displacement Range  :  0.100 inch (2.54 mm)
Displacement Resolution  :  0.0000009 inch or 0.9 micro-inch(0.00002 millimeter or 0.02 microns)
PLC Resolution for a 1 Sample :  0.00009%
Reproducibility Range  :  0.004 Percent Linear Change
Contact Load  :  113 grams
Temperature Control  :  User Programmable, 20-segment, PID Controller with Melting Point Protection
Heating Rate  :  1 to 30C/minuteProgrammable at 0.01C increments
Power Requirements  :  120vac/10amp or 240vac/5amp 50/60Hz
Data Acquisition  :  On-board Process controller - data stored at 1C increments, real-time data collection or data retrieval to computer
Data Analysis  :  Remote programming and analysis Software (Requires English Language Version of Windows OS)
Computer Interface  :  USB
Factory Calibration :   high purity platinum
Calibration Sample  :  99.8 Alumina; Platinum available as Option
Fused Silica Calibration Sample :   Optional
Bench-top Footprint (open)Length x Depth x Height  :  31 x 12 x 14 (788 x 305 x 356 mm)




Model 1410 STD




General

Orton dilatometer Model 1410STD is a horizontal, digital dilatometer that measures the expansion or contraction of a single test specimen from room temperature to 1000C with on-board, stand-alone, programmable process controller and linear motion measuring head assembly equipped with LVDT sensor.

Operated according to ASTM E-228, ASTM C-372, or ISO 7991


Includes
  • Bench top instrument console
  • 1000C split tube furnace
  • programmable process controller
  • LVDT measuring head
  • Fused quartz sample holder and probe rod
  • type "S" thermocouple
  • 1 (25.4mm) or 2" (50.8mm) calibration sample
  • computer software
  • Accessories and instruction manual. (Computer not included.)
Specification :

Model  :  DIL 1410 STD
Warranty  : 12 Months
Temperature Range  :  RT to 1,000C
Furnace  :  Clam shell style, 8 inch heated zone
Thermocouple  :  Type "S" 2 wire
Sample Holder and Probe Rod  :  Fused Quartz
Sample Size (max) :  50 mm long x 10 mm round or square
LVDT Displacement Range :   0.100 inch (2.54 mm)
Displacement Resolution :   0.0000009 inch or 0.9 micro-inch(0.00002 millimeter or 0.02 microns)
PLC Resolution for a 1 Sample :  0.00009%
Reproducibility Range  :  0.004 Percent Linear Change
Contact Load  :  Adjustable - minimum 4 grams
Temperature Control  :  User Programmable, 20-segment, PID Controller with Melting Point Protection
Heating Rate  :  1 to 30C/minuteProgrammable at 0.01C increments
Power Requirements  :  120vac/10amp or 240vac/5amp 50/60Hz
Data Acquisition :   On-board Process controller - data stored at 1C increments, real-time data collection or data retrieval to computer
Data Analysis  :  Remote programming and analysis Software (Requires English Language Version of Windows OS)
Computer Interface  :  USB
Factory Calibration :   high purity platinum
Calibration Sample  :  99.8 Alumina; Platinum available as Option
Water Cooled Bulkhead  :  Optional (water circulation system not included)
Measuring Head Cover :   Optional
Controlled Atmosphere Option  :  Optional
Fused Silica Calibration Sample  :  Optional
Bench-top Footprint; Length x Depth x Height  :  31 x 12 x 14 (788 x 305 x 356 mm)



Model 1412 STD




General

Orton dilatometer Model 1412STD is a horizontal, digital dilatometer that measures the expansion or contraction of a single test specimen from RT to 1200C with on-board, stand-alone, programmable process controller and linear motion measuring head assembly equipped with LVDT sensor.

Operated according to ASTM E-228, ASTM C-372, or ISO 7991

Includes
  • Bench top instrument console
  • 1200C split tube furnace
  • programmable process controller
  • LVDT measuring head
  • Alumina sample holder and probe rod
  • type "S" thermocouple
  • 1 (25.4mm) or 2" (50.8mm) calibration sample
  • computer software
  • Accessories and instruction manual. (Computer not included)

Specification :

Model  :  DIL 1412 STD
Warranty  :  12 Months
Temperature Range  :  RT to 1200C
Furnace  :  clam shell style, 8 inch heated zone
Thermocouple :   Type "S" 2 wire
Sample Holder and Probe Rod  :  Alumina (Fused Quartz optional)
Sample Size (max)  :  50 mm long x 10 mm round or square
LVDT Displacement Range :   0.100 inch (2.54 mm)
Displacement Resolution  :  0.0000009 inch or 0.9 micro-inch(0.00002 millimeter or 0.02 microns)
PLC Resolution for a 1 Sample  :  0.00009%
Reproducibility Range :  0.008 Percent Linear Change
Contact Load  :  Adjustable - minimum 4 grams
Temperature Control :   User Programmable, 20-segment, PID Controller with Melting Point Protection
Heating Rate  :  1 to 30C/minuteProgrammable at 0.01C increments
Power Requirements  : 120vac/10amp or 240vac/5amp 50/60Hz
Data Acquisition  : On-board Process controller - data stored at 1C increments, real-time data collection or data retrieval to computer
Data Analysis :   Remote programming and analysis Software (Requires English Language Version of Windows OS)
Computer Interface  :  USB
Factory Calibration :   high purity platinum
Calibration Sample  :  99.8 Alumina; Platinum available as Option
Water Cooled Bulkhead  :  Optional (water circulation system not included)
Measuring Head Cover :  Optional
Controlled Atmosphere Option  :  Optional
Bench-top Footprint (open)Length x Depth x Height  : 31 x 12 x 14 (788 x 305 x 356 mm)



Model 1416 STD






General

Orton dilatometer Model 1416STD is a horizontal, digital dilatometer that measures the expansion or contraction of a single test specimen from room temperature to 1600C with on-board, stand-alone, programmable process controller and linear motion measuring head assembly equipped with LVDT sensor.

Operated according to ASTM E-228, ASTM C-372, or ISO 7991

Includes
  • Bench top instrument console
  • 1600C water cooled furnace with SiC element
  • Programmable process controller
  • Alumina sample holder and alumina probe rod
  • type "S" thermocouple
  • 1 (25.4mm) or 2" (50.8mm) calibration sample
  • computer software
  • Accessories and instruction manual. (Computer not included.)
Specification :

Model  :  DIL 1416 STD
Warranty  : 12 Months
Temperature Range  :  RT to 1600C
Furnace  :  Tube style, 4 inch hot zone
Thermocouple  :  Type "S 3 wire
Sample Holder and Probe Rod  : Alumina (Fused Quartz optional)
Sample Size (max)  :  50 mm long x 10 mm round or square
LVDT Displacement Range  : 0.100 inch (2.54 mm)
Displacement Resolution  :  0.0000009 inch or 0.9 micro-inch(0.00002 millimeter or 0.02 microns)
PLC Resolution for a 1 Sample  :  0.00009%
Reproducibility Range  :  0.008 Percent Linear Change
Contact Load  :  Adjustable - minimum 4 grams / 3.9cn
Temperature Control  : User Programmable, 20-segment, PID Controller with Melting Point Protection
Heating Rate  : 1 to 20C/minute Programmable at 0.01C increments
Power Requirements  : 208-240vac, 20amp 50/60Hz
Data Acquisition  :  On-board Process controller - data stored at 1C increments, real-time data collection or data retrieval to computer
Data Analysis  :  Remote programming and analysis Software (Requires English Language Version of Windows OS)
Computer Interface  :  USB
Factory Calibration :   high purity platinum
Calibration Sample  : 99.8 Alumina (Platinum available as Option)
Water Cooled Bulkhead  :  Optional (water circulation system not included)
Measuring Head Cover  :  Optional
Controlled Atmosphere Option  : Optional
Vacuum 10-2 torr  :  Optional
Bench-top Footprint Length x Depth x Height  :  31 x 12 x 14 (788 x 305 x 356 mm)



Model 2010 C




General

Orton dilatometer Model 2010C is a horizontal, digital dilatometer that measures the expansion or contraction of a single test specimen from -190C to +500C or RT to 1000C with on-board, stand-alone, programmable process controller and linear motion measuring head assembly equipped with LVDT sensor.

Operated according to ASTM E-228, ASTM C-372, or ISO 7991

Includes

  • Bench top instrument console
  • 1000C split tube furnace
  • programmable process controller
  • Fused Quartz sample holder and Fused Quartz probe rod assembly
  • Liquid Nitrogen delivery system
  • Controlled Atmosphere components
  • Type "N" thermocouple
  • 1 (25.4mm) calibration samples
  • Computer software
  • Accessories and instruction manual. (Computer not included)
Specification :

Model  :  DIL 2010 C
Warranty :   12 Months
Temperature Range  :  RT to 1,000C or -190C to 500C
Furnace  :  Split Tube style, 12 inch heated zone
Thermocouple  :  Type "N 2 wire
Sample Holder and Probe Rod  :  Fused Quartz
Sample Size (max)  : 50 mm long x 10 mm round or square
LVDT Displacement Range  :  0.100 inch (2.54 mm)
Displacement Resolution  :  0.0000009 inch or 0.9 micro-inch (0.00002 millimeter or 0.02 microns)
PLC Resolution for a 1 Sample  :  0.00009%
Reproducibility Range  : 0.004 Percent Linear Change
Contact Load  Adjustable - minimum 4 grams
Temperature Control :   User Programmable, 20-segment, PID Controller with Melting Point Protection
Heating Rate  :  1 to 30C/minute Programmable at 0.01C increments
Power Requirements  : 120vac/10amp or 240vac/5amp 50/60Hz
Data Acquisition  :  On-board Process controller - data stored at 1C increments, real-time data collection or data retrieval to computer
Data Analysis  :  Remote programming and analysis Software (Requires English Language Version of Windows OS)
Computer Interface  :  RS232 or USB with adapter
Factory Calibration  :  high purity platinum
Calibration Sample  :  99.8 Alumina and Copper; Platinum available as Option
Water Cooled Bulkhead :  Optional (water circulation system not included)
Measuring Head Cover  : Included
Controlled Atmosphere Option  : Included
Fused Silica Calibration Sample  :  Optional
Bench-top Footprint (open) Length x Depth x Height  :  49 x 14 x 24 (1,250 x 360 x 600 mm)







 
 
 
 
PT. SPEKTRA SURYA UTAMA
 