Flame Photometer


ATS/40994 Science / Industry Flame Photometer




The model ATS/40994 – ATS 200S Science / Industry HPFP™ (High Performance Flame Photometer) is a multi-channel analyser that measures simultaneously and instantaneously up to 4 elements; Na, K, Li, and Ca are included as standard.

It uses powerful microprocessor and proprietary firmware that permits the analysis to be done through a menu driven routine. This allows for easy operation through a ’Yes / No’ menu-driven routine, minimising the variables due to human error.

This is the ideal instrument to speed up bulk sample analysis.

For the fully automated system, the model ATS/40998-4is offered. This unit includes the ATS LabAssistant™, and the ATS MiniSoftWin™ PC Professional Software to create a powerful, programmable, walk-away system.

Specification :


Measuring Ranges:

Na : 0 – 200 ppm; Li :  0 - 200 ppm; K :  0 – 200 ppm;
Ca :  0 – 200 ppm;  Ba : 30 – 3000 ppm (option)
Measuring Units : ppm, mmol/L, mEq/L
Sensitivity : typically 0.4 ppm Na and K
Detection Limit : 0.02 ppm for Na, K, Li, Ca
                            10 ppm for Ba
Linearity : Natural linearity extended multi-fold
Reproducibility : 2% CV for 10 consecutive measurements
Drift : 1 % over 30 min
Fuel Supply : Butane, Propane or LPG
Air Supply : air compressor with oil/water/dust filters
Dimensions and Weights: ATS/40994 Analyser: 320L X 400W X 400H mm; Net 9 kg, 230VAC, 50Hz or 110VAC, 60Hz
ATS Air Compressor: 340L x 250W x 350H mm; Net 6 kg. 230VAC, 50Hz or 110VAC, 60Hz



ATS/40997 Science/Industry Flame Photometer with Mg





The model ATS/40997 – ATS 200S Science/Industry HPFP™ with Mg (High Performance Flame Photometer) is a multi-channel analyer that measures simultaneously up to 4 elements; typically the hardware for Na, K, Mg, and Ca are included in the basic analyser with additional element channels available. Internal Standard comes as an additional extra.

The ATS/40997 uses powerful microprocessor and proprietary firmware that permits the analysis to be done through a menu driven routine. This allows for easy operation through a ’Yes / No’ menu-driven routine, minimising the variables due to human error. The latest model includes a laptop and ATS MiniSoftWin™ PC professional software.

The ATS/40998-7 includes the above and is designed for complete sample preparation automation and analysis results management. It includes the ATS LabAssistant™ and the ATS MiniSoftWin™ PC professional software. Please select below the separate flyer for further information.

Specification :

Measuring Ranges:
Na :  0 – 200 ppm;; K : 0 – 200 ppm;
Mg :  0 – 200 ppm;  Ca : 0 – 200 ppm;
Measuring Units : ppm, mmol/L, mEq/L
Sensitivity : typically 0.4 ppm Na and K
Detection Limit : 0.02 ppm for Na, K, Li, Ca
Linearity : Natural linearity extended multi-fold
Reproducibility : 1% CV for 10 consecutive measurements
Drift : 1 % over 30 min
Fuel Supply : Butane, Propane or LPG
Air Supply : air compressor with oil/water/dust filters
Ambient temperature: 15 – 36 °C
Ambient Humidity: up to 85% R. H. non-condensing
Dimensions and Weights: ATS/40997 Analyser: 320L X 400W X 400H mm; Net 9 kg, 230VAC, 50Hz or 110VAC, 60Hz
ATS Air Compressor: 340L x 250W x 350H mm; Net 6 kg. 230VAC, 50Hz or 110VAC, 60Hz



ATS/40998-4 – ATS 200S Science / Industry HPFP™ SYSTEM




The model ATS/40998-4 is a multi-channel analyser system that measures simultaneously and instantaneously 4 elements in a single aspiration; Na, K, Li, and Ca.

The system consists of the ATS/40994 analyser, the ATS LabAssistant™ with piston type precision auto-dilutor for micro volume dilutions, the ATS MiniSoftWin™ PC Professional Software, and an HP laptop creating a fully automated system delivering hands-off operation.

The ATS/40998-4 permits the analysis to be done through a menu driven routine via our proprietary software. This allows for easy methods development via PC keyboard allowing for final analytical data to be graphically displayed, mathematically adjusted, and final report print-out.

Specification :

Measuring Ranges:
Na : 0 – 200 ppm:  Li :  0 - 200 ppm; ; K:  0 – 200 ppm;
Ca :  0 – 200 ppm;  Ba : 30 – 3000 ppm (option)
Measuring Units : : ppm, mmol/L, mEq/L or other
Sensitivity : typically 0.4 ppm Na and K
Detection Limit  0.02 ppm for Na, K, Li, Ca(10 ppm for Ba)
Linearity : Natural linearity extended multi-fold
Reproducibility : 2 % CV for 10 consecutive measurements
Drift : 1 % over 30 min
Fuel Supply : Butane, Propane or LPG
Air Supply : air compressor with oil/water/dust filters
Dimensions and Weights: ATS/40994 Analyser: 320L X 400W X 400H mm; Net 9 kg, 230VAC, 50Hz or 110VAC, 60Hz
ATS Air Compressor: 340L x 250W x 350H mm; Net 6 kg. 230VAC, 50Hz or 110VAC, 60Hz



ATS/40998-7 Muti-Channel Flame Photometer SYSTEM with Mg





The model ATS/40998-7 – ATS 200S High Performance Flame Photometer™ System with Mg is a multi-channel analyser system that measures simultaneously and instantaneously up to 4 elements in a single aspiration. The hardware for Na, K, Mg, and Ca are included in the basic analyser with additional element channels available.

The system consists of the ATS/40997 Analyser, the ATS LabAssistant™ with piston type precision auto-dilutor for micro volume dilutions, the ATS MiniSoftWin™ PC Professional Software, and an HP laptop creating a fully automated system delivering hands-off operation.

The ATS/40998-7 permits the analysis to be done through a menu driven routine via our proprietary software. This allows for easy methods development via PC keyboard allowing for final analytical data to be graphically displayed, mathematically adjusted, and final report print-out.

Specification :

Measuring Ranges:
Na : 0 – 200 ppm;; Mg  : 0 - 200 ppm;  K :  0 – 200 ppm;
Ca :  0 – 200 ppm;  Ba : 30 – 3000 ppm (option)
Measuring Units : : ppm, mmol/L, mEq/L or other
Sensitivity : typically 0.4 ppm Na and K
Detection Limit 0.02 ppm for Na, K, Li, Ca(10 ppm for Ba)
Linearity : Natural linearity extended multi-fold
Reproducibility : 2 % CV for 10 consecutive measurements
Drift : 1 % over 30 min
Fuel Supply : Butane, Propane or LPG
Air Supply : air compressor with oil/water/dust filters
Dimensions and Weights: ATS/40997 Analyser: 320L X 400W X 400H mm; Net 9 kg, 230VAC, 50Hz or 110VAC, 60Hz
ATS Air Compressor: 340L x 250W x 350H mm; Net 6 kg. 230VAC, 50Hz or 110VAC, 60Hz


 
 
 
 
PT. SPEKTRA SURYA UTAMA
 